Modern Methods of Construction (MMC) deliver zero-carbon living only when engineering integrity, structural fire performance, and warranty clearances are mathematically proven before ground is broken.
Market Catalyst curates the commercial and technical data repository for Dragonboard magnesium sulphate (MgSO₄) stabilized composite Structural Insulated Panels (SIPs)—formulated with MgO, water, perlite, wood fibre, and bamboo fibre—providing architects, institutional funders, local authorities, and principal contractors with complete, unredacted test reports from Warringtonfire, FPA, BRE, Stroma, and UK accredited laboratories.
Certified BS EN 13501-1 Class A1 non-combustible facings combined with 198-minute loaded fire endurance (BS EN 1365-1) and FPA cladding test verification.
Achieves 0.12 W/m²K thermal transmittance and superior airtightness—proven in certified SAP 10 BREL compliance assessments and EPC Band A deployments.
Eurocode 5 structural testing validates axial and shear load-bearing capacity for residential multi-storey envelopes (demonstrated at Parkside Place 5-storey build).
Field Deployments & Case Studies
Independent, on-site structural installations demonstrating Category 2 Modern Methods of Construction (MMC) with Dragonboard Class A1 non-combustible panels across distinct building typologies.

The Lily House (Ebbw Vale)
Constructed with Dragonboard across interior and exterior walls, stairs, and architraves. Independently assessed by Stroma and BRE: achieved airtightness of 0.37 m³/(h·m²), EPC Band A (Score 112), and verified Green Guide Bespoke A-ratings.
View Stroma & BRE Dossiers→
Heswall Net Zero Residence
Two-year empirical indoor monitoring by University of Liverpool researchers: verified stable 50% relative humidity year-round, internal temperatures ≥16°C in winter and ≤24°C in summer, and zero energy bills.
Inspect University Monitoring Data→
Parkside Place (5-Storey)
Five-storey high-density residential housing scheme requiring full Category 2 MMC non-combustible verification, Eurocode 5 multi-storey axial racking clearance, and statutory building warranty compliance.
Read Parkside Place Dossier→
Finchley Residential Scheme
200 m² residential bungalow erected on-site in 2 days by two joiners using 175mm slim-profile DIP panels, maximising internal floor area while achieving sub-0.12 W/m²K thermal efficiency.
Read Finchley Dossier→Statutory Technical Parameters
Verified engineering properties extracted from accredited Warringtonfire, FPA, BRE, Stroma, and Lund University laboratory evaluations.
| Performance Parameter | Applicable Standard / Test Protocol | Demonstrated Value | Statutory & Warranty Status |
|---|---|---|---|
| Fire Performance Classification | BS EN 13501-1 (Reaction to Fire) / Rep. 531835 | Class A1 & A1FL Non-Combustible | Verified Zero Surface Spread of Flame |
| Loadbearing Fire Resistance | BS EN 1365-1 (Loaded Wall Assembly) / WF Rep. 539624/R | 198 Minutes Fire Resistance (>3.3 hrs) | Approved Document B Multi-Storey Compliant |
| Composite Panel Fire Integrity | BS 476 Part 22 / Exova Rep. 397336 | 243 Minutes Integrity (>4.0 hrs) | Party Wall Fire Compartmentation |
| Full-Scale Facade Fire Safety | BS 8414-2 Principles / FPA Rep. 106292.008 | Criteria Met / Certified Pass | Non-Combustible High-Rise Envelope |
| Envelope Thermal Transmittance | ISO 6946 / Elmhurst SAP 10 Compliance | 0.12 W/m²K (Wall System) | Exceeds Future Homes Standard 2025 |
| Core Binder Chemistry & Stability | Stoichiometric Formulation Analysis | MgO, MgSO₄, Perlite, Wood & Bamboo Fibre | Zero Chloride Migration / Non-Hygroscopic Phase |
| Acoustic Attenuation (Sound Reduction) | BS EN ISO 717 / ISO 10140-2 | Rw + Ctr > 54 dB Attenuation | Exceeds Approved Document E Mandates |
| Wall Robustness & Pull-Out Strength | BS 5234-2 / Anchorage Tests | Pass (Hard/Soft Impact & Crowd Pressure) | Direct Cabinet & Radiator Fixing Compatible |
Decarbonised Ground-to-Roof MMC Solutions
Eliminating on-site wet masonry, long cure cycles, and corrosion vulnerabilities. Deploying high-performance mineral composites from subterranean foundations to Euroclass A1 wall assemblies across residential master plans and marine modular structures.
High-Volume Offsite Party Wall Integration
Engaged in direct offsite specification for major residential developer programmes—including architectural detailing with Mattamy Homes and Q4A Architects for 2-hour non-combustible party wall fire separations across high-density townhouse schemes, eliminating traditional masonry cavity blockwork.
Marine & Modular Monocoque FabricationCross-Sector Transfer: Terrestrial to Marine
The same rot-proof, impermeable, and non-combustible composite mechanics proven in residential party walls scale seamlessly into marine monocoques, floating platforms, and flood-resilient civil infrastructure.
Advanced Mineral-Composite Substructure Systems
Engineered to replace carbon-intensive precast concrete in Modern Methods of Construction. By combining non-metallic mineral reinforcement with an impermeable, high-circularity matrix, this solution delivers rot-proof, zero-corrosion ground foundations with substantial deadweight savings.
Zero Steel Corrosion: Mineral rebar eliminates rust-jacking, carbonation loss, and concrete degradation in wet ground conditions.
Diverted Circular Streams: High-density matrix incorporates up to 85% diverted mineral by-products, directly supporting Net Zero carbon targets.
Logistical Efficiency: Up to 25% lighter than standard precast beams, reducing crane capacity requirements and road freight emissions.
Verified Testing & Institutional Standards Matrix
Evaluated against the stringent performance criteria of the British Board of Agrément (BBA), Building Research Establishment (BRE), and UK building warranty frameworks.
Reaction & Fire Resistance
- Reaction to Fire (EN 13501-1):Class A1 / A1FL
- Single Board (BS EN 1364-1):62 Minutes
- Dragon I Panel (BS 476 Pt 22):243 Minutes
- Loadbearing Wall (BS EN 1365-1):198 Minutes
- Facade Cladding (BS 8414-2):BR 135 Pass
Severe-Duty Mechanical Integrity
- Wall Stiffness (BS 5234-2):Pass (Severe Duty)
- Crowd Pressure Resistance:Pass
- Hard & Soft Body Impact:Zero Perforation
- Anchorage Pull-Out / Down:Fully Verified
Acoustic & Hygrothermal Shielding
- Internal Sound Insulation:BS EN ISO 717 Pass
- Vapour Resistance (UK R):15 MNs/g (Sd = 2.5m)
- Deliquescence & Crying Risk:Zero (0% MgCl₂)
- Mould & Flood Resilience:Impermeable
Virtual Data Room Index
Unredacted Warringtonfire test reports, SAP 10 BREL compliance reports, BRE thermal models, and fire safety test dossiers available for qualified professionals and institutional underwriters.
To prevent clutter and safeguard accredited testing intellectual property, all unredacted Warringtonfire, FPA, and BRE dossiers are accessed by professional registration of interest.
BRE Thermal Bridging Assessment Dossier: Lily House (28 Junctions & SAP Appendix K)
Complete BRE numerical analysis confirming whole-house y-value of 0.028 W/m²K and wall U-values of 0.15–0.16 W/m²K.
STROMA Green Guide Bespoke Rating Dossier: External Walls, Roofs & Floors
Official STROMA evaluations verifying A-ratings for external walls and roofs, and B-ratings for upper floors using Dragonboard composite assemblies.
Warringtonfire Loadbearing Fire Resistance Test Report (WF Rep. 539624/R)
Official BS EN 1365-1 fire test on a 175mm DragoniPanel loadbearing wall assembly under 100 kN vertical load, confirming 198 minutes loadbearing capacity.
Warringtonfire EN 13501-1 Reaction to Fire Classification (Rep. 531835)
Formal reaction-to-fire classification confirming Class A1 and A1FL non-combustibility for Dragonboard composite sheathing.
Formal reaction-to-fire classification confirming Class A1 and A1FL non-combustibility for Dragonboard composite sheathing.
Status: Accredited and verified for public inspection. Full unredacted laboratory dossiers are available via the secure access gateway below.
Fire Protection Association (FPA) R&D Cladding Test Report (Rep. 106292.008)
Large-scale fire test following BS 8414-2 principles on a self-supporting 175mm DragoniPanel façade with Terrix brick slips and polyurethane core.
Elmhurst Energy BREL Compliance & SAP 10 Assessment Report (Ebbdale Close)
As-designed Part L compliance report verifying 0.12 W/m²K wall U-value, 4.0 m³/(h·m²) air permeability, and net-zero carbon operation.
As-designed Part L compliance report verifying 0.12 W/m²K wall U-value, 4.0 m³/(h·m²) air permeability, and net-zero carbon operation.
Status: Accredited and verified for public inspection. Full unredacted laboratory dossiers are available via the secure access gateway below.
Exova Warringtonfire BS 476 Part 22 Fire Resistance Confirmation (Rep. 397336)
Non-loadbearing fire resistance testing confirming 243 minutes integrity and 173 minutes insulation for Dragonboard composite panel assemblies.
Lund University Moisture & Crying Board Post-Mortem (Talevska & Fakhro)
Academic verification confirming MgSO₄ binder stability, zero weeping/deliquescence, lowest moisture absorption (~5.5%), and complete elimination of unreacted free MgCl₂.
De-Risking Off-Site MMC Specification
Need independent technical due diligence on structural insulated panels, Warringtonfire test reports, or off-site supply chain readiness? Submit your site parameters for a 1-day desk appraisal.